The challenge
In a seismic zone, a mid-rise frame must stay stiff and ductile enough to protect occupants, while keeping columns and beams economical and coordinated with the architectural layout.
Our approach
- Built a 3D analysis model with floor diaphragms, load patterns and mass sources.
- Applied seismic loads to IS 1893 and wind loads to IS 875, and checked storey drift and torsional irregularity.
- Designed beams, columns and slabs to IS 456, with ductile detailing for seismic resistance.
- Prepared a Design Basis Report setting out assumptions, loads and methodology for review.
- Sized footings from support reactions and coordinated column positions with the architectural plans.
Deliverables
- 3D analysis model and results
- Design Basis Report (DBR)
- Beam, column and slab reinforcement schedules
- Foundation layout and details