The challenge
Coastal sites in the UAE combine shallow, saline groundwater with chloride-rich air. Concrete that would last decades inland can start corroding in a fraction of that time here, so durability has to be designed in, not added later.
Our approach
- Analysed the frame for gravity and lateral loads, and checked slab deflection and punching shear at columns.
- Chose a raft foundation to spread load evenly over variable, water-bearing ground and to limit differential settlement.
- Specified durability measures for the exposure class: increased concrete cover, a suitable cement type, a low water/cement ratio and protected reinforcement.
- Detailed below-ground waterproofing and protection boards around the raft and ground-floor slab.
- Coordinated with the architect and MEP engineers so openings and services did not weaken key structural members.
Deliverables
- Structural model and design calculations
- General arrangement and reinforcement drawings
- Foundation and waterproofing details
- Site support during inspections and concrete pours